MOXA TCC-82

SPHINX en Europe
ES
  • AT
  • BE
  • DK
  • FR
  • DE
  • IE
  • IT
  • NL
  • ES
  • SE
  • CH
  • UK
Productos grupos > Repeater > MOXA TCC-82

MOXA TCC-82

Serial Port Powered RS-232 4-channel Optical Isolator

MOXA TCC-82
1365_12292.png
1365_8813.png
1365_8814.png
1365_8815.png
1365_8816.png
1365_25854.jpg
1365_25855.jpg
  • EspecificacionesEspecificaciones
  • DescripciónDescripción
  • Más informaciónesMás informaciónes
  • PDFPDF
  • 4-channel 4 KV RMS Isolation for 1 minute
  • Dual self-powered or selectable external power source
  • Surge protection, 15 KV ESD
  • Auto baudrate sensing
  • Compact size
The TCC-82 provides full electrical isolation for bi-directional serial communication between two RS-232 devices in a compact, industrial-grade package. Both sides of an RS-232 connection are isolated optically to provide perfect protection against lightning surges, accidental high voltage shorts, and ground loops. The built-in, wide range isolators are tested to ensure that they can withstand more than 4 kV rms input to output for 1 minute. This means that the TCC-82 not only meets the requirements of general serial data communications, but also the high standards required by industrial automation and medical applications. The TCC-82 protects the TxD and RxD data lines, and also protects the RTS and CTS handshake lines for a total of 4 isolated channels to provide complete protection of your RS-232 applications.

External Power Source Not Required

The TCC-82 supports port-powered operation, which means that it can obtain power directly from the attached serial devices. Power is obtained from the RS-232 TxD, RTS, or DTR lines, regardless of whether the signal is high or low, eliminating the need for an external power supply. However, external power can be used if handshake lines are not available, if the serial cable is too long, or if the serial device is a low powered device. For external power, the TCC-82 can use a 5 to 12 VDC adaptor or a USB power cord. Note that both sides of the connection are powered independently, so if necessary, one side can rely on port power and the other on an external power source.
When installing the TCC-82, we recommend that you connect all output signals. The TCC-82 obtains power from these signals even if they are not used by your system. Care should be taken when choosing the external power supply if your application requires the full 4 kV of isolation. Most commercial power supplies provide only 1500 VAC isolation between the primary and secondary windings. If you are using external power for both sides of the TCC-82, make sure that separate power sources are used, each with sufficient isolation protection.

ProdGrafik
            

Serial Communication

 Female DB9 Side
  (Bi-Directional
  Reversible
  Connector)
 Signals: Pass through TxD, RxD, RTS, and CTS
 Loop back: RTS to CTS, DTR to DSR and DCD
 RS-232 Male
 DB9 Side
 Signals: Pass through TxD, RxD, RTS, and CTS
Loop back: DTR to DSR and DCD
 Baudrate  50 bps to 115.2 Kbps
 Surge protection  15 KV ESD
 Optical Isolation  4 KV RMS for 1 minute

Environmental

 Operating
 Temperature
 0 to 60°C (32 to 140°F)
 Storage
 Temperature
 -20 to 75°C (-4 to 167°F)
 Humidity  5 to 95% RH

Power Consumption

 Input Power Source  Serial RS-232 Port: TxD, RTS, DTR; Ext Power Input (jack)
 Input Power
  Protection
 5 to 12 VDC
 Power Consumption  10 mA @ 5 VDC

Mechanical

 Dimensions
 (W x D x H)
 42 x 80 x 23.6 mm
 Case  ABS
 Weight  60 ± 5g

Regulatory Approvals

 TCC-82  CE Class B, FCC Class B

Ordering Information

 TCC-82  Serial Port Powered RS-232 Isolator w/4 KV Isolation and 15 KV ESD Surge Protection
 All items include:  - USB Power Cord
 - User’s Manual