MOXA ioLogik E2210

Active Ethernet I/O with Ethernet and 12 Digital Inputs, 8 Digital Outputs

MOXA ioLogik E2210
1391_12198.png
1391_1926.jpg
1391_1928.jpg
1391_1929.jpg
1391_12199.jpg
  • EspecificacionesEspecificaciones
  • DescripciónDescripción
  • Más informaciónesMás informaciónes
  • PDFPDF
  • Instant Event Reporting by TCP/UDP/e-mail/SNMP trap
  • Easy Local Control without Programming by Patented Click&Go Logic
  • 2-point 24VDC digital input with DI/Event counter
  • 8 points 24VDC digital output as pulse output
  • 10/100Mbps Ethernet with Modbus/TCP protocol Connecting up to 10 hosts
  • SNMP to I/O mapping that works with Network Management System
  • Windows VB and Windows/WinCE/Linux C API
  • Peer-to-Peer I/O without controller

Active Ethernet I/O is an exciting new breed of Ethernet I/O that introduces active I/O messaging with easy logic control. Absolutely no programming is required to configure the I/O server’s control logic, due to the patented and intuitive Click&Go™ interface. Bi-directional and direct input-to-output signal communication over Ethernet is supported, and Windows/Linux APIs are included for use in both industrial automation and IT environments.

 

Improve system efficiency via real-time data acquisition
Unlike traditional passive remote I/O, Active Remote I/O provides Active I/O messaging that can send message over Ethernet, TCP/IP network on I/O input status changes or meets certain condition, the message is sent to host computer. Communication between the host computer and Active Remote I/O device is concise and efficient. In addition, the message delivery time is 20 times faster than traditional SCADA systems (50 ms compared to 1 sec).

No programming! Hassle-free Click&Go logic control
Click&Go logic is the key to make ioLogik E2000 series become an intelligent remote I/O. Click&Go logic lets you decide when to send I/O data, and what to say to host computers for simple alarm control and messaging.

As opposed to using C-language or PLC-ladder, a person who understands basic logic concepts can do the configuration themselves, and easily finish their projects. Unlike passive remote I/O architecture, you can integrate Active Remote I/O’s input signals into one event to be an integrated message, and set up local output control at the same time. The unique Click&Go logic is a patent pending technology developed by Moxa.

Unique LCD Display Module for on-site configuration
ioLogik E2000 series Active Remote I/O provides an optional LCD display module for on-site management and configuration. The unique display module can display network and I/O settings, e.g. analog input value, digital input counter value. The IP, netmask address can be set locally without carrying a PC.

Independent Configuration for Multi-functional DI and DO points
Each digital input can be configured independently for DI or Event Counter mode, and each digital output can be independently configured for DO or Pulse Output mode.

ProdGrafik

ioLogik E2210 Specifications

Inputs and Outputs

Digital Inputs
12 channels

Digital Outputs
8 channels

Isolation
3k VDC or 2k Vrms


Digital Input

Sensor Type
Wet Contact (NPN), Dry Contact

I/O Mode
DI or Event Counter

Dry Contact
  • On: short to GND
  • Off: open

Wet Contact (DI to GND)
  • On: 0 to 3 VDC
  • Off: 10 to 30 VDC

Common Type
12 points per COM

Counter Frequency
900 Hz

Digital Filtering Time Interval
Software Configurable


Digital Output

Type
Sink

I/O Mode
DO or Pulse Output

Pulse Output Frequency
1 kHz

Over-voltage Protection
45 VDC

Over-current Protection
2.6 A (4 channels @ 650 mA)

Over-temperature Shutdown
175°C (min.)

Current Rating
200 mA per channel


Power Requirements

Power Consumption
203 mA @ 24 VDC


MTBF (mean time between failures)

Time
213,673 hrs

Database
Telcordia (Bellcore)



Common Specifications

LAN

Ethernet
1 10/100 Mbps RJ45 port

Protection
1.5 kV magnetic isolation

Protocols
Modbus/TCP, TCP/IP, UDP, DHCP, BOOTP, SNMP, HTTP, CGI, SNTP, SMTP


Serial Communication

Interface
RS-485-2w: Data+, Data-, GND (3-contact terminal block)

Serial Line Protection
15 kV ESD for all signals


Serial Communication Parameters

Parity
None

Data Bits
8

Stop Bits
1

Flow Control
None

Baudrate
1200 to 115200 bps

Protocol
Modbus/RTU


Power Requirements

Power Input
24 VDC nominal, 12 to 36 VDC


Physical Characteristics

Wiring
I/O cable max. 14 AWG

Dimensions
115 x 79 x 45.6 mm (4.53 x 3.11 x 1.80 in)

Weight
under 250 g

Mounting
DIN rail or wall


Environmental Limits

Operating Temperature
Standard Models: -10 to 60°C (14 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)

Storage Temperature
-40 to 85°C (-40 to 185°F)

Ambient Relative Humidity
5 to 95% (non-condensing)

Altitude
Up to 2000 m
Note Please contact us if you require products guaranteed to function properly at higher altitudes.


Standards and Certifications

Safety
UL 508

EMI
EN 61000-3-2; EN 61000-3-3; EN 61000-6-4;

FCC
Part 15, Subpart B, Class A

EMS
EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5,
EN 61000-4-6, EN 61000-4-8, EN 61000-4-11, EN 61000-6-2

Shock
IEC 60068-2-27

Freefall
IEC 60068-2-32

Vibration
IEC 60068-2-6

Green Product
RoHS, CRoHS, WEEE



Ordering Information

Available Modules
ioLogik E2210 Active Ethernet I/O with 12 digital inputs and 8 digital outputs
ioLogik E2210-T Active Ethernet I/O with 12 digital inputs and 8 digital outputs, -40 to 75°C operating temperature