Productos grupos > Device Server > MOXA NPort 5650

MOXA NPort 5650

8/16-port RS-232/422/485 Rackmount Serial Device Servers

MOXA NPort 5650
1399_12654.png
1399_8681.jpg
1399_8682.png
  • EspecificacionesEspecificaciones
  • DescripciónDescripción
  • Más informaciónesMás informaciónes
  • PDFPDF
  • 8 or 16 serial ports supporting RS-232/422/485
  • Standard 19-inch rackmount size
  • 10/100M auto-sensing Ethernet
  • Easy IP address configuration with LCD panel (excluding wide temperature models)
  • Configure via Telnet/Web/Windows utility
  • Socket modes: TCP server/TCP client/UDP/Real COM
  • SNMP MIB-II for network management
  • Universal high-voltage range: 100 to 240 VAC or 88 to 300 VDC
  • Popular low-voltage ranges: ±48 VDC (20 to 72 VDC, -20 to -72 VDC)
With the NPort® 5600 rackmount series, you not only protect your current hardware investment, but also allow for future network expansion by centralizing the management of your serial devices and distributing management hosts over the network.

Network Readiness for up to 16 Serial Devices

Only basic configuration is needed with the NPort® 5600 to connect up to 16 serial devices to an Ethernet network.

19-inch Rackmount Device Server
NPort® 5600 device servers come with Tx/Rx LEDs for the serial ports on the front panel, and 8 or 16 RJ45 serial port connectors on the rear panel. This makes the NPort® 5600 device servers suitable for standard 19-inch rack mounting, allowing you to simplify operational, maintenance, and administrative tasks.

Real COM/TTY Ports
Real COM/TTY drivers are provided to make the serial ports on the NPort® 5600 recognizable as Real COM ports by Windows, or Real TTY ports by Linux. In addition to supporting basic data transmission and reception, the NPort® drivers also support the RTS, CTS, DTR, DSR, and DCD control signals.

LED Indicators to Ease Your Maintenance Tasks
The System LED, serial Tx/Rx LEDs, and Ethernet LEDs (located on the RJ45 connector) provide a great tool for basic maintenance tasks and help engineers analyze problems in the field. The LEDs not only indicate current system and network status, but also help field engineers monitor the status of attached serial devices.

Adjustable Termination and Pull High/Low Resistors
When using termination resistors to prevent serial signal reflection, it is important to set the pull high/low resistors correctly so that the electrical signal is not corrupted. Since no set of resistor values is universally compatible for all environments, the NPort® 5650-8/16 has DIP switches on the bottom panel for setting the termination and pull high/low resistor values.

ProdGrafik
LAN   
Ethernet 10/100 Mbps, RJ45, Auto MDI/MDIX
Protection Built-in 1.5 KV magnetic isolation
Serial
Interface RS-232/422/485, 8-pin RJ45
Signals RS-232: TxD, RxD, RTS, CTS, DTR, DSR, GND, DCD
RS-422: Tx+, Tx-, Rx+, Rx-, GND
RS-485 (2-wire): Data+, Data-, GND
RS-485 (4-wire): Tx+, Tx-, Rx+, Rx-, GND
RS-485 Data Direction Control Patented Automatic Data Direction Control (ADDC™)
Serial line protection 15 KV ESD for all signals
Power line protection 1 KV Burst (EFT), EN61000-4-4
0.5 KV Surge, EN61000-4-5
Optical Fiber  
Distance Multi mode: 0 to 2 km, 1310 nm (62.5/125 µm, 500 MHz*km)
Single mode: 0 to 40 km, 1310 nm (9/125 µm, 3.5 PS/(nm*km)
Min. TX Output Multi mode: -20 dBm
Single mode: 0 to 40 km, -20 dBm
Max. TX Output Multi mode: -14 dBm
Single mode: 0 to 40 km, 0 dBm
Sensitivity -36 to -32 dBm (Single), -34 to -30 dBm (Multi)
Advanced Built-in Features  
HMI LCM display with four push buttons
Buzzer Yes
Real-Time Clock Yes
Watch Dog Timer Yes
Serial Communication Parameters  
Parity None, Even, Odd, Space, Mark
Data bits 5, 6, 7, 8
Stop bit 1, 1.5, 2
Flow control RTS/CTS, DTR/DSR (NPort 5610 only), XON/XOFF
Speed 50 bps to 921.6 Kbps Software Features
Protocols ICMP, IP, TCP, UDP, DHCP, BootP, Telnet, DNS,
SNMP, HTTP, SMTP, SNTP, PPP, SLIP, RTelnet, RFC2217
Utilities NPort Administration Suite for Windows 95/98/ME/NT/2000/XP/2003 
OS Driver Support Windows 95/98/ME/NT/2000/XP/2003/XP x64/2003 x64 COM driver, Linux Real TTY driver, SCO Unix, SCO OpenServer 5, UnixWare 7, UnixWare 2.1.x, SVR4.2/QNX
Configuration Web/Telnet console, or Windows utility
Power Requirements  
Power Input 100 to 240 VAC, 47 to 63 Hz
Power Consumption NPort 5650-8/16: 158 mA @ 100 VAC, 102 mA @ 240 VAC
NPort 5650-S-SC-8/16: 164 mA @ 100 VAC, 110 mA @ 240 VAC
Port 5650-M-SC-8/16: 174 mA @ 100 VAC, 113 mA @ 240 VAC
Mechanical  
Material SECC sheet metal (1 mm)
Environmental  
Operating Temperature 0 to 55°C (32 to 131°F), 5 to 95% RH
Storage Temperature -20 to 75°C (-4 to 167°F), 5 to 95% RH
Regulatory Approvals  
EMC CE: EN55022 Class A/EN 55024
IEC 61000-4-12 (for NPort 5610-16, NPort 5610-8-48)
FCC: FCC Part 15 Subpart B Class A
Safety UL: UL60950-1, TÜV: EN60950-1


 
Ordering Information 
NPort 5650-8 8-port RS-232/422/485 rackmount device server with RJ45 connectors and
100-240 VAC power input
NPort 5650-8-M-SC 8-port RS-232/422/485 rackmount device server with multi-mode fiber (SC connector)
NPort 5650-8-S-SC 8-port RS-232/422/485 rackmount device server with single-mode fiber (SC connector)
NPort 5650-8-T 8-port RS-232/422/485 rackmount device server with RJ45 connectors and
100-240 VAC power input, -40 to 75°C operating temperature
NPort 5650-8-HV-T 8-port RS-232/422/485 to rackmount device server with RJ45 connectors
and 88 to 300 VDC power input, -40 to 85°C operating temperature
NPort 5650-16 16-port RS-232/422/485 rackmount device server with RJ45 connectors
and 100-240 VAC power input
NPort 5650-16-M-SC 16-port RS-232/422/485 rackmount device server with multi-mode fiber (SC connector)
NPort 5650-16-S-SC 16-port RS-232/422/485 rackmount device server with single-mode fiber (SC connector)
NPort 5650-16-T 16-port RS-232/422/485 rackmount device server with RJ45 connectors and
100-240 VAC power input, -40 to 75°C operating temperature
NPort 5650-16-HV-T 16-port RS-232/422/485 to rackmount device server with RJ45 connectors and
88 to 300 VDC power input, -40 to 85°C operating temperature
Above items include:
  • 8/16-port serial device server x 1
  • Quick Installation Guide
  • NPort Document and Software CD
  • Power Cord
Optional Accessories  
CBL-RJ45M9-150 RJ45 (8-pin) to male DB9 cable, 150 cm
CBL-RJ45F9-150 RJ45 (8-pin) to female DB9 cable, 150 cm
CBL-RJ45M25-150 RJ45 (8-pin) to male DB25 cable, 150 cm
CBL-RJ45F25-150 RJ45 (8-pin) to female DB25 cable, 150 cm
  