MOXA EDS-P510 Series
7+3G-port Gigabit managed Ethernet switches with 4 IEEE 802.3af PoE ports
- Advanced PoE management function (PoE port setting, PD failure check, and PoE scheduling)
- Command Line Interface (CLI) for quickly configuring major managed functions
- IPv6 Ready logo awarded (IPv6 Logo Committee certified)
- Software-based IEEE 1588 PTPv2 (Precision Time Protocol) for precise time synchronization of networks
- DHCP Option 82 for IP address assignment with different policies Download Moxa 2015 IES brochure!
- Support EtherNet/IP and Modbus/TCP protocols for device management and monitoring
- Turbo Ring and Turbo Chain (recovery time < 20 ms @ 250 switches), RSTP/STP, and MSTP for network redundancy
- IGMP snooping and GMRP for filtering multicast traffic
- Port-based VLAN, IEEE 802.1Q VLAN, and GVRP to ease network planning
- QoS (IEEE 802.1p/1Q) and TOS/DiffServ to increase determinism
- Port Trunking for optimum bandwidth utilization
- TACACS+, IEEE 802.1X, SNMPv3, HTTPS, and SSH to enhance network security
- Lock port function for blocking unauthorized access based on MAC address
- SNMPv1/v2c/v3 for different levels of network management
- RMON for efficient network monitoring and proactive capability
- Bandwidth management to prevent unpredictable network status
- Port mirroring for online debugging
- Automatic warning by exception through e-mail, relay output
The EDS-P510 series Gigabit managed redundant Ethernet switches come standard with 4 10/100BaseT(X) 802.3af (PoE) compliant Ethernet ports and 3 combo Gigabit Ethernet ports. The EDS-P510 switches provide up to 15.4 watts of power per PoE port, and allow power to be supplied to connected devices (such as surveillance cameras, wireless access points, and IP phones) when AC power is not readily available or is cost-prohibitive to provide locally. The EDS-P510 switches are highly versatile, and their SFP fiber port can transmit data up to 80 km from the device to the control center with high EMI immunity. The Ethernet switches support advanced management and security features. The EDS-P510 series is designed especially for security automation applications such as IP surveillance, and gate of entry systems, which can benefit from a scalable backbone construction and Power-over-Ethernet support
Technology
Standards
IEEE 802.3af for Power-over-Ethernet
IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X) and 100BaseFX
IEEE 802.3ab for 1000BaseT(X)
IEEE 802.3z for 1000BaseX
IEEE 802.3x for Flow Control
IEEE 802.1D-2004 for Spanning Tree Protocol
IEEE 802.1w for Rapid STP
IEEE 802.1s for Multiple Spanning Tree Protocol
IEEE 802.1Q for VLAN Tagging
IEEE 802.1p for Class of Service
IEEE 802.1X for Authentication
IEEE 802.3ad for Port Trunk with LACP
Protocols
IGMPv1/v2, GMRP, GVRP, SNMPv1/v2c/v3, DHCP Server/Client, DHCP Option 66/67/82, BootP, TFTP, SNTP, SMTP, RARP, RMON, HTTP, HTTPS, Telnet, SSH, Syslog, EtherNet/IP, Modbus/TCP, SNMP Inform, LLDP, IEEE 1588 PTPv2, IPv6, NTP Server/Client
MIB
MIB-II, Ethernet-Like MIB, P-BRIDGE MIB, Q-BRIDGE MIB, Bridge MIB, RSTP MIB, RMON MIB Group 1, 2, 3, 9
Flow Control
IEEE 802.3x flow control, back pressure flow control
Switch Properties
Priority Queues
4
Max. Number of Available VLANs
64
VLAN ID Range
VID 1 to 4094
IGMP Groups
1024
MAC Table Size
8 K
Packet Buffer Size
1 Mbit
Interface
Fiber Ports
100/1000BaseSFP slot
RJ45 Ports
10/100BaseT(X) or 10/100/1000BaseT(X) auto negotiation speed
PoE Pinout
V+, V+, V-, V- for pin 1, 2, 3, 6 (Endspan, MDI Alternative A)
Console Port
RS-232 (RJ45 connector)
DIP Switches
Turbo Ring, Master, Coupler, Reserve
LED Indicators
PWR1, PWR2, FAULT, 10/100/1000, 10/100, MSTR/HEAD, CPLR/TAIL, PoE
Alarm Contact
2 relay outputs with current carrying capacity of 0.5 A @ 48 VDC
Digital Inputs
2 inputs with the same ground, but electrically isolated from the electronics.
- +13 to +30V for state “1”
- -30 to +3V for state “0”
- Max. input current: 8 mA
Power Requirements
Input Voltage
48 (46 to 50 V) VDC, redundant dual inputs
Input Current
Max. 1.62 A @ 48 VDC (supports up to 4 ports at 15.4 W per PoE port)
Overload Current Protection
Present
Connection
2 removable 6-contact terminal blocks
Reverse Polarity Protection
Present
Physical Characteristics
Housing
Metal, IP30 protection
Dimensions
80.2 x 135 x 105 mm (3.16 x 5.31 x 4.13 in)
Weight
1170 g
Installation
DIN-rail mounting, wall mounting (with optional kit)
Environmental Limits
Operating Temperature
Standard Models: 0 to 60°C (32 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
Storage Temperature
-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity
5 to 95% (non-condensing)
Standards and Certifications
Safety
UL 508
EMI
FCC Part 15 Subpart B Class A, EN 55022 Class A
EMS
EN 61000-4-2 (ESD) Level 3, EN 61000-4-3 (RS) Level 3, EN 61000-4-4 (EFT) Level 3,
EN 61000-4-5 (Surge) Level 3, EN 61000-4-6 (CS) Level 3, EN 61000-4-8
Marine
DNV, GL, LR, ABS, NK
Shock
IEC 60068-2-27
Freefall
IEC 60068-2-32
Vibration
IEC 60068-2-6
MTBF (mean time between failures)
Time
205,384 hrs
Database
Telcordia (Bellcore), GB
Ordering information:
Standard Operating Temperature Models
Model No. | Description |
EDS-P510 | Managed Gigabit Ethernet switch with 3 10/100BaseT(X) ports, 4 PoE 10/100BaseT(X) ports, and 3 10/100/1000BaseT(X) or 100/1000BaseSFP slots combo ports, 0 to 60°C |
Managed Ethernet Switches – Extended Temperature
Model No. | Description |
EDS-P510-T | Managed Gigabit Ethernet switch with 3 10/100BaseT(X) ports, 4 PoE 10/100BaseT(X) ports, and 3 10/100/1000BaseT(X) or 100/1000BaseSFP slots combo ports, -40 to 75°C |
DIN Rail Power Supplies
Model No. | Description |
DR-75-48 | 75W/1.6A DIN-Rail 48 VDC power supply with universal 85 to 264 VAC input |
DR-120-48 | 120W/2.5A DIN-Rail 48 VDC power supply, 88 to 132 VAC / 176 to 264 VAC input by switch |
Accessories - SNMP OPC Server Pro Software
Model No. | Description |
EDS-SNMP OPC Server Pro | CD with EDS-SNMP OPC Server Pro Software and Manual |
Backup Configurator
Model No. | Description |
ABC-01 | Automatic Backup Configurator through the RS-232 console port, 0 to 60°C |
Mounting Kits
Model No. | Description |
RK-4U | 4U-high 19” rack mounting kit |
WK-46 | Wall mounting kit |
SFP-1G Modules
Model No. | Description |
SFP-1GSXLC | for 0.5 km transmission, 0 to 60°C |
SFP-1GLSXLC | SFP module with 1 1000BaseSX port with LC connector for 2 km transmission, 0 to 60°C |
SFP-1GLXLC | SFP module with 1 1000BaseLX port with LC connector for 10 km transmission, 0 to 60°C |
SFP-1GLHXLC | SFP module with 1 1000BaseLHX port with LC connector for 40 km transmission, 0 to 60°C |
SFP-1GZXLC | SFP module with 1 1000BaseZX port with LC connector for 80 km transmission, 0 to 60°C |
SFP-1GEZXLC | SFP module with 1 1000BaseEZX port with LC connector for 110 km transmission, 0 to 60°C |
SFP-1G10ALC | WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 10 km transmission, TX 1310 nm, RX 1550 nm, 0 to 60°C |
SFP-1G10BLC | WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 10 km transmission, TX 1550 nm, RX 1310 nm, 0 to 60°C |
SFP-1G20ALC | WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 20 km transmission, TX 1310 nm, RX 1550 nm, 0 to 60°C |
SFP-1G20BLC | WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 20 km transmission, TX 1550 nm, RX 1310 nm, 0 to 60°C |
SFP-1G40ALC | WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 40 km transmission, TX 1310 nm, RX 1550 nm, 0 to 60°C |
SFP-1G40BLC | WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 40 km transmission, TX 1550 nm, RX 1310 nm, 0 to 60°C |
SFP-1GSXLC-T | SFP module with 1 1000BaseSX port with LC connector for 0.5 km transmission, -20 to 75°C |
SFP-1GLSXLC-T | SFP module with 1 1000BaseSX port with LC connector for 2 km transmission, -40 to 85°C |
SFP-1GLXLC-T | SFP module with 1 1000BaseLX port with LC connector for 10 km transmission, -40 to 85°C |
SFP-1GLHXLC-T | SFP module with 1 1000BaseLHX port with LC connector for 40 km transmission, -40 to 85°C |
SFP-1GZXLC-T | SFP module with 1 1000BaseZX port with LC connector for 80 km transmission, -40 to 85°C |
SFP-1G10ALC-T | WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 10 km transmission, TX 1310 nm, RX 1550 nm, -40 to 85°C |
SFP-1G10BLC-T | WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 10 km transmission, TX 1550 nm, RX 1310 nm, -40 to 85°C |
SFP-1G20ALC-T | WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 20 km transmission, TX 1310 nm, RX 1550 nm, -40 to 85°C |
SFP-1G20BLC-T | WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 20 km transmission, TX 1550 nm, RX 1310 nm, -40 to 85°C |
SFP-1G40ALC-T | WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 40 km transmission, TX 1310 nm, RX 1550 nm, -40 to 85°C |
SFP-1G40BLC-T | WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 40 km transmission, TX 1550 nm, RX 1310 nm, -40 to 85°C |
SFP-FE Modules
Model No. | Description |
SFP-1FEMLC-T | SFP module with 100Base multi-mode with LC connector for 4 km transmission, -40 to 85°C |
SFP-1FESLC-T | SFP module with 100Base single-mode with LC connector for 40 km transmission, -40 to 85°C |
SFP-1FELLC-T | SFP module with 100Base single-mode with LC connector for 80 km transmission, -40 to 85°C |
Ordering Information SFP Modules | Available Models | Port Interface | Standard Temperature (-40 to 85°C) | Wide Temperature (0 to 60°C) | 1000BaseSX, LC Connector, 0.5 km | 1000BaseLSX, LC Connector, 2 km | 1000BaseLX, LC Connector, 10 km | 1000BaseLH, LC Connector, 30 km | 1000BaseLHX, LC Connector, 40 km | 1000BaseZX, LC Connector, 80 km | 1000BaseEZX, LC Connector, 100 km |
SFP-1GSXLC | SFP-1GSXLC-T∗ | 1 | --- | --- | --- | --- | --- | --- |
SFP-1GLSXLC | SFP-1GLSXLC-T | --- | 1 | --- | --- | --- | --- | --- |
SFP-1GLXLC | SFP-1GLXLC-T | --- | --- | 1 | --- | --- | --- | --- |
SFP-1GLHLC | SFP-1GLHLC-T | --- | --- | --- | 1 | --- | --- | --- |
SFP-1GLHXLC | SFP-1GLHXLC-T | --- | --- | --- | --- | 1 | --- | --- |
SFP-1GZXLC | SFP-1GZXLC-T | --- | --- | --- | --- | --- | 1 | --- |
SFP-1GEZXLC | --- | --- | --- | --- | --- | --- | --- | 1 |
∗Note: SFP-1GSXLC-T: -20 to 75°C operating temperature
Ordering Information WDM-type (BiDi) SFP Modules | Available Models | Port Interface | Standard Temperature (0 to 60°C) | Wide Temperature (-40 to 85°C) | 1100BaseSFP, LC Connector, 11 km | 1100BaseSFP, LC Connector, 20 km | 1100BaseSFP, LC Connector, 40 km |
TX 1311 nm, RX 1550 nm | TX 1550 nm, RX 1311 nm | TX 1311 nm, RX 1550 nm | TX 1550 nm, RX 1311 nm | TX 1311 nm, RX 1550 nm | TX 1550 nm, RX 1311 nm | ||
SFP-1G11ALC | SFP-1G11ALC-T | 1 | --- | --- | --- | --- | --- |
SFP-1G11BLC | SFP-1G11BLC-T | --- | 1 | --- | --- | --- | --- |
SFP-1G20ALC | SFP-1G20ALC-T | --- | --- | 1 | --- | --- | --- |
SFP-1G20BLC | SFP-1G20BLC-T | --- | --- | --- | 1 | --- | --- |
SFP-1G40ALC | SFP-1G40ALC-T | --- | --- | --- | --- | 1 | --- |
SFP-1G40BLC | SFP-1G40BLC-T | --- | --- | --- | --- | --- | 1 |