1-port PROFIBUS-to-PROFINET gateways

MOXA MGate 5102-PBM-PN Series
3669_12626.png
3669_8621.png
  • EspecificacionesEspecificaciones
  • DescripciónDescripción
  • Más informaciónesMás informaciónes
  • PDFPDF
  • Protocol conversion between PROFIBUS and PROFINET Download Moxa´s MGate Gateway Brochure and White Paper
  • Automatic scan of PROFIBUS devices, and easy configuration
  • microSD card for configuration backup
  • Built-in Ethernet cascading for easy wiring
  • Redundant dual DC power inputs and relay output supported
  • Embedded I/O monitoring and diagnostic tools
  • Web-based GUI for I/O data visualization
  • -40 to 75°C wide operating temperature models available
  • Supports Moxa´s MXview industrial network management software via the MXview Plug-in
The MGate 5102-PBM-PN gateway provides a communication portal between PROFIBUS devices (e.g., PROFIBUS PLC or drive) and the PROFINET host. All models are protected with a rugged metallic casing, are DIN rail mountable, and offer optional built-in optical isolation. The PROFIBUS and Ethernet status LED indicators are provided for easy maintenance. The rugged design is suitable for industrial applications such as oil & gas, power, process automation, and factory automation.

Easy Setup Tools

Both the Windows MGate Manager utility and web console support the AutoScan function, which makes configuration and operation easy. AutoScan automatically detects all connected PROFIBUS slave devices and their available I/O modules, allowing you to configure your gateways very quickly, and a data mapping table is provided. Furthermore, one click is all that’s needed to export all PROFIBUS I/O modules to a GSDML file to assist in the configuration of the PROFINET controller (e.g., a Siemens PLC).

Various Maintenance Functions

The MGate 5102-PBM-PN provides a web console and Telnet console for remote maintenance, with both consles supporting encryption commutation functions such as HTTPS and SSH to prevent unauthorized access. The status and changes in I/O data of all PROFIBUS slaves can be monitored remotely via the web console, and users can also review the log from the web console to see which system events have occurred. A relay output alarm is provided for the power input and Ethernet cable status. These functions make it easy for maintenance engineers to troubleshoot and maintain devices.

ProdGrafik

    Ethernet Interface

    Protocol
    • PROFINET RT
    Number of Ports
    • 2 (1 IP)
    Speed
    • 10/100 Mbps, Auto MDI/MDIX
    Connector
    • 8-pin RJ45
    Magnetic Isolation Protection
    • 1.5 kV built-in



    PROFIBUS Interface

    Protocol
    • PROFIBUS DP-V1 Master
    Number of Ports
    • 1
    Data Rate
    • 9600 bps to 12 Mbps
    Connector
    • DB9 female
    Isolation
    • 2 kV (built-in)



    Serial Signals (Serial Console)

    Connector
    • 8-pin RJ45
    RS-232
    • TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND



    Software

    Configuration Options
    • Windows utility, serial console, web console (HTTP/HTTPS), Telnet/SSH console
    Utilities
    • MGate Manager for Windows 2000, Windows XP/2003/Vista/2008/7 x86/x64



    Physical Characteristics

    Housing
    • Metal
    Weight
    • 500 g
    Dimensions
    • 36 x 105 x 140 mm (1.42 x 4.13 x 5.51 in)



    Environmental Limits

    Operating Temperature
    • Standard Models: 0 to 60°C (32 to 140°F)
    • Wide Temp. Models: -40 to 75°C (-40 to 167°F)
    Storage Temperature
    • -40 to 85°C (-40 to 185°F)
    Ambient Relative Humidity
    • 5 to 95% (non-condensing)



    Power Requirements

    Input Voltage
    • 12 to 48 VDC
    Power Connector
    • Terminal block
    Power Consumption
    • 430 mA @ 12 VDC



    Standards and Certifications

    Safety
    • UL 508, EN 60950-1
    Hazardous Location
    • UL/cUL Class 1 Division 2 Groups A/B/C/D, ATEX Zone 2 (pending)
    EMC
    • CE, FCC
    EMI
    • EN 55022 Class A, FCC Part 15 Subpart B Class A
    EMS
    • EN 55024,
    • EN 61000-4-2 (ESD) Level 3,
    • EN 61000-4-3 (RS) Level 3,
    • EN 61000-4-4 (EFT) Level 4,
    • EN 61000-4-5 (Surge) Level 3,
    • EN 61000-4-6 (CS) Level 3,
    • EN 61000-4-8,
    • EN 61000-4-11,
    • EN 61000-4-12
    Shock
    • IEC 60068-2-27
    Freefall
    • IEC 60068-2-32
    Vibration
    • IEC 60068-2-6



    Reliability

    MTBF (mean time between failures)
    • 980,417 hrs




Ordering Information

           Available Modules
MGate 5102-PBM-PN 1-port PROFIBUS-to-PROFINET gateway, 12-48 VDC, 0 to 60°C operating temperature
MGate 5102-PBM-PN-T 1-port PROFIBUS-to-PROFINET gateway, 12-48 VDC, -40 to 75°C operating temperature





Los clientes que han visto este artículo también vieron
Accept

This website uses cookies to provide the best possible experience. More information.