Advantech EKI-5726

SPHINX en Europe «  ch uk de fr at dk it nl be  «
Tel..: +34 933 396 542 |  Informaciones Legales |  Contáctanos |  FAQ |  Blog
      Lupe

Estás aquí « Advantech EKI-5726 »

Advantech EKI-5726

prodgraf


16-port Gigabit Ethernet ProView Switch



especificaciones


descripción

The EKI-5726/I is the world’s first convergence switch for process control and IT networking management. This series uses Modbus/TCP to communicate with the SCADA software and SNMP to communicate with the NMS (Networking Management System) at the same time, thereby allowing full read control over the devices either for control engineers or for IT. The devices come with the Port-based QoS for deterministic data transmission allows the priority ports to prioritize the traffic coming over those ports and delay the less immediately necessary data over the remaining ports. The EKI-5726/I switch uses the highest quality components, to enable the range to operate in temperatures of between -40 and 75°C along with EMS Level 3 protection to repel electromagnetic interface for industrial resistance.



ProdGrafik

más informaciónes


Communications

Standard
IEEE 802.3, 802.3u, 802.3x, 802.1p, 802.3az, 802.3ab

LAN
10/100/1000Base-T(X)

Transmission Distance
Up to 100 m

Transmission Speed
Up to 1000 Mbps


Interface

Connectors
16 x RJ45
6-pin removable screw terminal (power & relay)

LED Indicators
P1, P2, P-Fail, Loop detection
10/100/1000T(X): Link/Activity, Speed


Switch Properties

MAC Table Size
8K

Packet Buffer Size
4.1M bit

Switching Capacity
32 Gbps

Jumbo Frame
9216 bytes

Power

Power Consumption
Max. 8 W

Power Input
12~48 V DC (8.4~52.8 V DC), redundant dual inputs

Fault Output
1 Relay Output


Mechanism

Dimensions (W x H x D)
74 x 120 x 84 mm

Enclosure
IP30, metal shell with solid mounting kits

Mounting
DIN-Rail, Wall


Protection

Reverse Polarity
Present

Overload Current
Present


Environment

Operating Temperature
EKI-5726: -10~60°C (14~140°F)
EKI-5726I: -40~75°C (-40~167°F)

Storage Temperature
-40 ~ 85°C (-40 ~ 185°F)

Operating Humidity
10 ~ 95% (non-condensing)

Storage Humidity
10 ~ 95% (non-condensing)

MTBF
2,788,343 hours


Certification

Safety
IEC/EN60950, UL60950, UL508, Class 1 Division 2, ATEX

EMI
FCC Part 15 Subpart B Class A, EN 55011/55022
Class A

EMS
EN 61000-4-2 (Level 3)
EN 61000-4-3 (Level 3)
EN 61000-4-4 (Level 3)
EN 61000-4-5 (Level 3)
EN 61000-4-6 (Level 3)
EN 61000-4-8 (Level 3)

Shock
IEC 60068-2-27

Freefall
IEC 60068-2-32

Vibration
IEC 60068-2-6



Ordering Information

EKI-5726
EKI-5726I



PDF

descripción PDF Advantech EKI-5726 Datasheet (425.1 kB)

plus   

Más productos de este grupo



Copyright © 2013 SPHINX Computer Vertriebs GmbH

CGVhasta ContáctanosDirectiva CookiesOficinasQuiénes somos